1, determine the pressure:

The actual maximum pressure selected metering pump rated pressure slightly higher than the required, generally higher than the 10 to 20%. Do not choose too high, too high pressure will waste energy, increase investment and operating costs of equipment.

2, determine the flow rate:

The flow rate of the selected metering pump should be equal to or slightly greater than the flow rate required by the process. The use range of the metering pump flow is 30 to 100% of the rated flow rate of the metering pump, and the repetition precision of the metering pump is high at this time. Considering the economical and practical, it is suggested that the actual demand of the metering pump is 70 to 90% of the rated flow rate of the metering pump.

3, determine the material of the pump head (Ye Liduan):

After determining the specific type and specification of the metering pump, we choose the material of the overcurrent part according to the properties of the overflowing medium. This step is very important. If it is not selected properly, it will cause the corrosion of the medium, damage the overflowing parts or media, and leak the pollution system. Serious accidents can also be caused in serious cases. If you are not sure, please consult our company.


Other aspects:

When you choose the metering pump, you also need to consider the precision level of the required metering pump, and the higher the precision level, the greater the input. The general working temperature of the metering pump is at - 30~100 C, and the working temperature range of the special metering pump is wider. For example, the high temperature liquid metering pump with thermal insulation jacket can deliver 500 degrees of temperature. For granularity of medium, we should be less than 0.1mm. For medium larger than 0.1mm, the flow structure of pump can be changed to meet the need. For the viscosity of the medium, the general should be 0 ~ 1000mm/s, the special metering pump up to 6000 mm2/s. mechanical diaphragm metering pump flow is the maximum flow rate measured under the rated pressure of the calibration (room temperature water transportation), if the pressure drops, the output flow can be higher than the calibration.